Plug the Deutsch 4-pin DTM connector on the AQ1 Data Logger harness into the
mating connector on other AEMnet compatible devices. See “Using the AQ1 Data
Logger” for more information on configuring the AEMnet.
INPUT SIGNALS
Analog 1-4 are 0-5V analog inputs with optional pull-up resistor for RTD/Thermistor-
style sensor. Examples: AEM gauges, MAP/pressure sensors, TPS/APP/shock
travel/load cell sensors, analog MAF sensors, any 2 wire RTD or thermistor style temp
sensor. See “Using the AQ1 Data Logger” for more information on configuring Inputs 1-
4. The corresponding wires in the harness for Analog 1-4 are Yellow and are labeled
INPUT 1, INPUT 2, INPUT 3 and, INPUT 4.
Analog/Frequency 5-8 are analog inputs for that can optionally measure frequency (0-
5 V or 0-16 V) Examples: RPM, vehicle speed, frequency based MAF, injector duty
cycle, boost control solenoid, flow sensor, hall sensor, any 3 wire pressure sensor. See
“Using the AQ1 Data Logger” for more information on configuring Inputs 5-8. The
corresponding wires in the harness for Analog/Frequency 5-8 are Yellow and are
labeled INPUT 5, INPUT 6, INPUT 7, and INPUT 8.
Connection diagrams are shown below for some of the more common sensors/signals
to be used with Inputs 1-4 and Inputs 5-8. See Figure 2.
Figure 2. AEM Pressure Sensors(Left) AEM Temp Sensor (Right)