Aem Infinity Supported Applications - Universal V8 Eng Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16
© 2014 AEM Performance Electronics
MSD Distributor + ATI Flying Magnet + Honeywell GT101 Sensor
1. Modify and install mechanical distributor. (See Modifying Mechanical Advance Distributor, in this
document.)
2. Install ATI Flying Magnet crank trigger. (Note that an adjustable sensor mount is not provided with the
ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between magnet targets with the engine at TDC. Set sensor air gap to .053”.
3. Wiring:
Crank Sensor – Honeywell GT-101 Sensor
Cam Sensor – Modified MSD Distributor
Desc
Connect To
Wire
Desc
Connect To
+12V sensor
power
Main relay power out
Black/
Purple
Cam signal +
C1-48 Cam Pos Sens 1 VR+
Sensor ground
C1-20 Sensor Ground
Black/
Orange
Cam signal -
C1-47 Cam Pos Sens 1 VR-
Crank signal
C1-21 Crk Pos Sens
Hall
Note: Use shielded twisted pair wiring w/drain to ground.
Note: Use shielded wiring with drain to ground.
4. Load ATI 12 + GT101 base session and review Setup Wizard. (See Setup Wizard, in this document.)
5. Sync ignition timing. (See Syncing Ignition Timing, in this document.)
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 45 46

Commentaires sur ces manuels

Pas de commentaire